120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine

- Dec 21, 2017 -

120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Basic Info

  • Model NO.: ADFS

  • Installation Method: Fixed

  • Cooling Method: Air Cooled

  • Open Type Diesel Generator Speed: Speed

  • Usage: Common Units, Standby Unit, Emergency Crew

  • Excitation Mode: Static Exciter

  • Rated Frequency: 200-1000Hz

  • Rated Output: 3-Phase Single Phase

  • Open Type Diesel Generator Origin: China

  • Type: Open Type Silent Type Automatic Type Trailer Type

  • Stroke: Four Stroke

  • Output Type: AC Three Phase

  • Conditions of Use: Customized

  • Open Type Diesel Generator Landuse Type of Unit: Low Noise Automation Type

  • Rated Power: 10-1200kVA

  • Rated Speed: 1500,1800,2000,2200,2400,3000rpm

  • Diesel Engine: Commins Engine

  • Open Type Diesel Generator Transport Package: Standard Export Save Packing

  • HS Code: 8501620000

120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Product Description

Open Type Diesel Generator Specifications 
 

Rated Power: 10-1200kVA
 
Rated Frequency: 200-1000Hz
Rated Speed: 1500,1800,2000,2200,2400,3000r/min
Rated Output: 3-phase or single phase
Power Factor: 0.3-1.0 (standard: pf=0.8lag)
Diesel Engine:Cummins Engine
Overall Types
1 Open type - Diesel generator without enclosure,
  automatic contral or trailer.
2 Silent type - Diesel generator with rainproof and   acoustic-attenuated enclosure
3 Automatic type - Diesel generator with automatic   contral
4 Trailer type - Diese generator with trailer         mounted.



120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Technical Features

Specialized structure designs:
Comparing to common grid-frequency diesel generators, the mid-frequency generators have many differencies in structure designs to ensure the reliability of machine. Therefore, the mid-frequency diesel generators require much higher technical level and production to the supplier.
Fujian Ideal Electric is one of the ealiest suppliers in China for mid-frequency diesel generators and has accumulated abundance experience in the design and production of the products. The products have been used in Euro and Asia with good quality reputation for many years




 
Ventilation:
One of the most important factors to decide the reliability mid-frequency diesel generators is the ventilation (cooling) design. Especially in the application of inductive heating, the ventilation issue appears to be more essential because of the big working current.
The ventilation structure of the products have been made after careful caculations in the air inlet area and the outlet area, as well as the path of air flow to get the maxmum cooling effect.
Open Type Diesel Generator Corrosion Preventing:
Galvanized steel structure enlosure providing the good resistance to corrosion.
Application of the double layers painting ( one layer of expocy primer  and a layer of oil-proof external painting) provides the best protection for the enclosure from corrosion and rust
Open Type Diesel Generator Sound-proof materials:
The latest coated acoustic-attenuated material is applied to provide best soundproof effect as well as complete reliability and safety for long-term service.
Strong machanical fastening is applied on the ceiling and other necessary locations applied to provide long-term safety.
Liffting and forking points:
Both top lifting (two points or one point) and base lifting are enabled, along with the bottom forking points. It provides the big convenience for the users in moving the machines.
Lifting points are made of high-strength steel and designed with abundant mechanical strength margin to ensure the complete safety.
Dual speed operation mode
If necessory, the products can be designed to operate normally at 1500r/min and 1800nr/min to get different frequencies. This feature requires high technical level and high production quality to the suppliers, but bring great convenience to the users in flexible operation.
Exhauste Design
If no specified, the exhaust outlet is on the top of soundproof mid-frequency diesel generators, and is mounted with the flexible rainproof cap. 
120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Muffler:
If no specified, the mufflers are installed inside the enclosure in order to get more compact total size of the mid-frequency diesel generators.
The mufflers are wrapped with the latest insulating materials to ensure the cooler inside space of the enclosure.
120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Contral box design:
If no specified, the contral box of the genset should be removable structure with best vibration damping. This brings big convenience for users to install. repare and maintain the contral system, as well as ensures the reliable operation of the contral system.
The conral box is mounted with easy-opening windows to enable easy observation during the machine operation. 
120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Factory test:
All products have most strict factory tests before delivery. The tests meet the highest requirements in international standards and China national standards to provide best guarantee of quality. 
 
120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Mechanical Safety:
All parts have been installed in firmly and all mechanical connections have been fastened securely during the production. 
All hinges, door handles and other mechanical parts are sturdy and durable, and have been mounted firmly.
Best vibration damping measures have been applied to ensure the full reliability and long service life of the products.
 
120kVA 400Hz 3-Phase 208V Super Silent Diesel Generator with Cummins Engine Electrical Safety:
To-earth insulation test with the test voltage up to 3000V have been made in generator and electrical contral parts to ensure completely electrical safety.
Temperature sensors have been installed at the hottest spots in the generator to provide easy monitor for operation status and safety.
Earthing bolts have been welded on enclosure and base to provide the reliable electric earthing.